Engtips - March 12, 2024. Are you helping your patients with type 1 diabetes make the most of continuous glucose monitoring (CGM) devices? At the Advanced Technologies & …

 
JAE (Structural) 9 Feb 11 21:01. Sounds like you got it. wannabeSE (Civil/Environmental) 9 Feb 11 21:13. If you are anchoring the equipment to masonry or concrete, look at ASCE 7-05 section 13.4.2. You may need to multiply the seismic force by 1.3. Also, if the anchors are not prequalified for seismic, you may need to …. Ticketmase

Analyze the purlin as a beam with fixed ends and design your connection for that moment with a healthy amount of extra capacity. I am using the current code required snow loads. In my area, the required snow load is 35psf, so I am not overly worried about wind. JStructsteel (Structural) 1 Nov 22 12:45.22 hours ago · Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Boiler and Pressure Vessel engineering. (38965 members) forum794 - Professional forum and technical support for engineers for Boiler and Pressure Vessel engineering. Includes problem solving collaboration tools. Forum. Search.May 1, 2017 · Fluid Power engineering. (8465 members) forum1083 - This group is to allow those who use hydraulics and/or pneumatics to exchange ideas and information that will assist in their proper use and that the discussions will illustrate the need for and promote interest in gaining appropriate certification. Forum. Search. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …LIVERPOOL, England (AP) — Liverpool was denied a last-minute penalty after fighting back to draw 1-1 with Manchester City on Sunday in the final Premier League …Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng …Financial planners explain how to balance stocks and bonds in your 401(k). Your age plays a major factor. By clicking "TRY IT", I agree to receive newsletters and promotions from M...Civil/Environmental engineering general discussion. (46845 members) forum194 - Professional forum and technical support for engineers for Civil/Environmental engineering general discussion. Includes problem solving collaboration tools. Forum.Eng-Tips. 291 likes · 1 talking about this. ENG-TIPS FORUMS: GIVING NEW MEANING TO "VALUE ENGINEERING"1st Orifice: Do = 0.51 mm & L = 50 mm ; Pressure drop at Max flow : 6.89 kg/cm2_g. 2nd orifice: Do = 0.51 mm & L = 50.83 mm ; ; Pressure drop at Max flow : 3.44 kg/cm2_g. Data sheet mentions that both are restriction (choke) type venturi. However, when I calculated critical pressure under the given condition to check the whether the …Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: SOLIDWORKS 3D Design. Includes problem solving collaboration tools.Eng-Tips. 291 likes · 1 talking about this. ENG-TIPS FORUMS: GIVING NEW MEANING TO "VALUE ENGINEERING"Construction Process2. Construction Process. 2. As a new junior engineer without much construction experience, I wanted to ask whether there is a trustworthy resource which goes into a detailed narrative of the construction process, encompassing from the beginning paperwork, typical teams making up a project, …Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register …ENG-TIPS. ENG-TIPS stands out as one of the most popular portals for engineer communities on the web, and it’s easy to see why. There are over 18 specific …May 29, 2023 · Apartment Building Collapse46. "A six-story apartment complex partially collapsed Sunday evening in the city of Davenport, Iowa, authorities said. It was not immediately clear if there were any fatalities or how many people may be missing or trapped in the building. Davenport Mayor Mike Matsen said there were "several people unaccounted for ... The reason is carbon content below 0.03% would be considered 304L per the SA 240 material specification, and limited to 1000 deg F. When you have dual grade certification 304L/304, the 0.04% or higher carbon comes into play for creep strength and one must review the MTR for specific use. SnTMan (Mechanical) 14 …But, I expand on them a little: 1) Handbook of Steel Connection Design and Details by Akbar Tamboli. 2) The Following AISC design guidess: a) DG1: Base Plates. b) DGs 4 & 16 for bolted end plate moment connections. c) DGs 12 & 13 for retrofit of existing moment connections and stiffeners for moment … Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for DASSAULT: SOLIDWORKS 3D Design. Includes problem solving collaboration tools.Dynamic Cone Penetrometer (DCP) is a very poor tool for evaluating modulus of subgrade reaction (k) or modulus of rupture (M R).In my opinion, you would be better off guessing - at least then you would be applying your judgement to the problem.Jan 3, 2021 · PE Civil Structural Exam Study Advice9. Hello All! I am preparing to take the PE Civil Structural exam for the first time in October 2021. Please reply with what each of you used to study and pass the exam. I have found a lot of engineers who recommend the CERM book and NCEES Civil Structural Practice Exam book. The Bahamas are a staple on warm-weather cruises. Read on for all you need to know when planning a sailing to the cruise industry's most popular destination. If you've cruised or a...Design of Footing with very large moment. Good day! I believe this one is just simple, what makes it complex is the large moment to be considered in the design. I have an anchored steel pole with base reactions M=220kN-m, P=28kN, V=14kN,. (M=moment, P=Axial, V=Shear). I have already design the pedestal to …UcfSE (Structural) 29 Nov 06 21:52. A good limit for live load deflection is 3/4-inch. You don't want to squash your interior partitions either, besides just the windows and such in the exterior walls. Some manufacturers have products designed to go allow more than 3/4 inches of deflection but it isn't the norm.Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng …Civil/Environmental engineering general discussion. (46845 members) forum194 - Professional forum and technical support for engineers for Civil/Environmental engineering general discussion. Includes problem solving collaboration tools. Forum. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Eng-Tips aims to support students’ professional and academic development. Engineering information and connections for the global community of engineers. Find engineering games, videos, jobs, disciplines, calculators and articles… UcfSE (Structural) 29 Nov 06 21:52. A good limit for live load deflection is 3/4-inch. You don't want to squash your interior partitions either, besides just the windows and such in the exterior walls. Some manufacturers have products designed to go allow more than 3/4 inches of deflection but it isn't the norm.Bolt assembly stress vs. allowable stress. When assembling flanged joints, a typical target bolt stress is 40-70% of its SMYS, see e.g. ASME PCC-1 Appendix O. If you look at the allowable stresses for bolt materials (e.g. SA-193-B7) in ASME II Part D, you will find that these are much lower. That is, when …Financial planners explain how to balance stocks and bonds in your 401(k). Your age plays a major factor. By clicking "TRY IT", I agree to receive newsletters and promotions from M...Note that if you select either pinned or fixed, you are departing from reality already, as the connection is unlikely to fit either exactly. So it could be modeled as intermediate in various ways as well. If you neglect deflections in the roof unrelated to this load, you are departing from reality.Strut-Tie Model - Exterior Joint. Under the section of Geometry of the STM and Forces, he states the column moment is half the nominal beam moment. No end conditions are given for either the beam or the column, so I am lead to believe that simple moment equilibrium about the intersecting centre would result in the column moment …Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search …Eng-Tips has a very active NX forum. Its large user base with varied experience can answer most any question related to NX. Anyone can lurk in the forum, but a free registration …Student Engineer General Discussion. (4380 members) forum1630 - Professional forum and technical support for engineers for Student Engineer General Discussion. Includes problem solving collaboration tools. Forum.Headed stud vs. deformed bar as an anchor. On the left is a headed stud that we can say is governed by concrete tension breakout. On the right is a deformed rebar with an embedded length equal to ld per 25.4.2.3 of ACI 318-14. Let's say I wanted to design an anchor for a wall.The first one is applying point load on the flange and the Beff that can be used for capacity calculation. Mu = P x a. S = beff x t^2 / 6. Mc = phi x fy x S. Second image is the scenario with stiffener added. How do we calculate the capacity for such cases? Thanks.thread404-515636. Dynamo2000 (Mechanical) (OP) 19 Jan 24 21:00. Very recently in the news was an invention called the Holo Tile Floor created by Disney's National Inventors Hall of Fame member Lanny Smoot. This creation allows the user to "walk" in any direction without moving anywhere! The floor shifts to compensate for the user's leg …Engineering Reference. Free Engineering Books Pdf Is The Best Wanted Website For All Engineers. Download Free Engineering Books Online Which Related To All Engineering …The new search is useless, but hopefully the features of the legacy search will be reinstated soon. CWB1 (Mechanical) 28 Jan 24 16:22. I usually have better luck applying search codes like "site:eng-tips.com" in a commercial search engine like google, duckduckgo, etc rather than version of those same engines that are on the websites …HVAC/R engineering. (27384 members) forum403 - Professional forum and technical support for engineers for HVAC/R engineering. Includes problem solving collaboration tools. Search.Brick grows with time, and that can lead to cracking at the thinnest sections, and the two sections in your photos are thin. This cracking in veneer is not indication of settlement or other structural problems, so if it bothers you, get a mason to repoint it. Make sure he knows what he is doing, as amateur repairs can stand out worse than the ...hybrid steel/CLT structure. I'm looking to get a better understanding of using CLT deck with gyp concrete topping, supported by steel beams and columns for a five story institutional building. Specifically, what to pay attention to when using the CLT as a floor diaphragm sending lateral forces to concrete shear walls or braced frames for the LFRS.It's defined in chapter 14 for ASCE 7-05 as a wall segment with a horizontal length-to-thickness ratio of at least 2.5, but not exceeding 6, whose clear height is at least two times its horizontal length. Believe the definition in ASCE 7-10 is the same. Essentially a wall pier is a portion of an overall wall that would have a …Analyze the purlin as a beam with fixed ends and design your connection for that moment with a healthy amount of extra capacity. I am using the current code required snow loads. In my area, the required snow load is 35psf, so I am not overly worried about wind. JStructsteel (Structural) 1 Nov 22 12:45.Will and Mango from Part-Time Genius explore the subject of rudeness — why it's dangerous to our health and why we can't stop thinking about it. Advertisement Someone cuts you off ...Civil/Environmental engineering general discussion. (46845 members) forum194 - Professional forum and technical support for engineers for Civil/Environmental engineering general discussion. Includes problem solving collaboration tools. Forum.Eng-Tips aims to support students’ professional and academic development. Eng-Tips is a forum for engineering professionals and students of all disciplines. (Stock photo.)Join Eng-Tips Forums! Talk With Other Members; Be Notified Of Responses To Your Posts; Keyword Search; One-Click Access To Your Favorite Forums; Automated Signatures On Your Posts; Best Of All, It's Free! Join Us! *Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting …Petroleum engineering general discussion. (13755 members) forum481 - Professional forum and technical support for engineers for Petroleum engineering general discussion. Includes problem solving collaboration tools. Pipelines, Piping and Fluid Mechanics engineering. forum378 - Professional forum and technical support for engineers for Pipelines, Piping and Fluid Mechanics engineering. Includes problem solving collaboration tools. See thread507-434895: Tension Field Action - End panels in Old Codes. BA. rb1957 (Aerospace) 7 Sep 20 22:16. the author makes the point that the end bays usually don't have the stiffener at the extreme end of the beam, and so the web cannot develop the shear buckles. In the example R13 posted these end panels aren't doing anything to react the ... Eng-Tips Forums is an English-language knowledge market website that allows users to post engineering-related questions to be answered and answer questions asked by other users. The targeted audience of Eng-Tips is engineering professionals. Eng-Tips. @engtips. The Eng-Tips resource library offers the latest engineering white papers, webcasts, and product information. eng-tips.nethawk.net …Existing 2 storey 40+ yr old house all walls as 4" brick exterior with 4" block backup, with bond bricks turned every 7th course. I believe that this is considered as an 8" masonry bearing wall...not 4" load bearing block with 4" veneer. The building depts around are extremely quick to call out 'brick veneer' can't be used for connecting or ...RE: Required Bolt Area of standard flange. TGS4(Mechanical)1 Apr 06 17:26. You should also refer to ASME PCC-1. As far as the "required" bolt area goes, the B16.5 standard specifies bolt sizes to use, and, like codeeng says, you are allowed to design to the pressures/temperatures listed in B16.5, RE: Required Bolt Area of standard flange. Finite Element Analysis (FEA) engineering. (36618 members) forum727 - Professional forum and technical support for engineers for Finite Element Analysis (FEA) engineering. Includes problem solving collaboration tools. Forum. Jan 3, 2021 · PE Civil Structural Exam Study Advice9. Hello All! I am preparing to take the PE Civil Structural exam for the first time in October 2021. Please reply with what each of you used to study and pass the exam. I have found a lot of engineers who recommend the CERM book and NCEES Civil Structural Practice Exam book. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register …Joints spacing: • Rule of thumb is 24 to 36 times the thickness (gives the spacing in mm/inches). • Keep the thickness variation to -5mm (-1/4") / +10mm (3/8"), and the subgrade as flat as possible with no abrupt change greater than 15mm (1/2") in about 1.2m (4'). This keeps the "sudden" restraint potential down. Posting in the Eng-Tips forums is a member-only feature. Click Here to join Eng-Tips and talk with other members! Already a Member? Login. Professional forum and technical support for engineers for Engineering project management general discussion. Includes problem solving collaboration tools. March 12, 2024. Are you helping your patients with type 1 diabetes make the most of continuous glucose monitoring (CGM) devices? At the Advanced Technologies & …Subject: Section VIII-1, UCS-85 (b) and (e) Date Issued: May 31, 1984. File Number: BC82-563. Related Documents: Question (1): A dished head made of P-No. 1 Gr. Nos. 1 and 2 material with a thickness of less than 1¼ in. is hot pressed at a temperature of 1750°F. Are test specimens required under UCS-85 of Section VIII, Division 1, to ...My 1937 copy of Trautwines Civil Engineers Reference Book gives: "Normal reinforcing steel ultimate strength of between 50,000 - 70,000 lbs per sq in with elastic limit (yield) at 25,000 - 35,000 lbs per sq in. Cold working the bars will raise the elastic limit to 40,000 - 50,000 lbs per sq in. Deformed bars have a higher elastic limit claimed ...Qatar has for months been criticized for mistreating migrant workers. Qatar, one of the world’s richest countries and the winner of the bid to host the soccer World Cup in 2022, ha...Although not directly applicable for stacks TIA/EIA-222 'Structural Standards For Steel Antenna Towers And Supporting Structures' states "Initial tension in the guys, for design purposes, is normally 10 percent of the published breaking strength of the strand with upper and lower limits of 15 and 8 percent …The new search is useless, but hopefully the features of the legacy search will be reinstated soon. CWB1 (Mechanical) 28 Jan 24 16:22. I usually have better luck applying search codes like "site:eng-tips.com" in a commercial search engine like google, duckduckgo, etc rather than version of those same engines that are on the websites …It's defined in chapter 14 for ASCE 7-05 as a wall segment with a horizontal length-to-thickness ratio of at least 2.5, but not exceeding 6, whose clear height is at least two times its horizontal length. Believe the definition in ASCE 7-10 is the same. Essentially a wall pier is a portion of an overall wall that would have a …Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng …Note that if you select either pinned or fixed, you are departing from reality already, as the connection is unlikely to fit either exactly. So it could be modeled as intermediate in various ways as well. If you neglect deflections in the roof unrelated to this load, you are departing from reality.The current ASME VIII require you to obtain U stamp certification from the ASME Board. They will issue to you, based on extensive testing of your design and fabrication capability, experience and understanding of the current ASME code requirements. No specific PD 5500 requirements. Please note that this month is … Civil/Environmental engineering general discussion. (46863 members) forum194 - Professional forum and technical support for engineers for Civil/Environmental engineering general discussion. Includes problem solving collaboration tools. Forum. I want to summarize as follows: Rule 1) The direction of the coordinate axis should align with the direction from "Grid A to Grid B" of the bush element. Rule 2) The "positive" direction of your coordinate system …Jan 26, 2024 · The new search is useless, but hopefully the features of the legacy search will be reinstated soon. CWB1 (Mechanical) 28 Jan 24 16:22. I usually have better luck applying search codes like "site:eng-tips.com" in a commercial search engine like google, duckduckgo, etc rather than version of those same engines that are on the websites themselves. Pressure/temperature ratings for Class 800 shall be determined by the equation: P8 = 1/3 P6 + 2/3 P9. where. P8 is the pressure at the specified temperature, expressed in bar3, for Class 800 rounded to the nearest. (10 kpa); P6 is the listed pressure, at the specified temperature, for Class 600, expressed in bar;Cut Weight for Ring Forgings... thread794-517252. MVPs. ring forgings (Mechanical) (OP) 12 Mar 24 16:20. Hello all,

GEE8B (Structural) 29 Apr 23 08:33. Dead load is always downward (direction of gravity). Wind load can be upward or downward (suction/pressure). Wind forces away from the surface are (-). Wind forces towards the surface are (+). So the “W” in 0.6D+W can be negative or positive. Pressure and suction values are typically per ASCE7, and it is .... Verizon outage map by zip code near me

engtips

Design of Footing with very large moment. Good day! I believe this one is just simple, what makes it complex is the large moment to be considered in the design. I have an anchored steel pole with base reactions M=220kN-m, P=28kN, V=14kN,. (M=moment, P=Axial, V=Shear). I have already design the pedestal to … Boiler and Pressure Vessel engineering. (38965 members) forum794 - Professional forum and technical support for engineers for Boiler and Pressure Vessel engineering. Includes problem solving collaboration tools. Forum. Search. In ASCE 7-22, partially open is included in those. My assumption is that they messed up and forgot to include it in ASCE 7-16. My tin-foil hat opinion: Partially open was added simply because we aren't comfortable labeling buildings that are THAT "open" as "enclosed."While specific laws vary by state, the general process of assessing real property is similar across the country. If you own real estate, it will be assessed, and that assessment w... Corrosion engineering. (24764 members) forum338 - Professional forum and technical support for engineers for Corrosion engineering. Includes problem solving collaboration tools. Forum. Search. Ayurveda. Unani. Homeopathy. Cowpathy. You’ve heard of ayurveda, the traditional Indian medical science. So have you about Unani, the Perso-Arabic healing science. Then there is ho...The Bahamas are a staple on warm-weather cruises. Read on for all you need to know when planning a sailing to the cruise industry's most popular destination. If you've cruised or a...Join Eng-Tips Forums! Talk With Other Members; Be Notified Of Responses To Your Posts; Keyword Search; One-Click Access To Your Favorite Forums; Automated Signatures On Your Posts; Best Of All, It's Free! Join Us! *Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting …For starters, you can successfully weld 5052 H32 (not heat treatable aluminum alloy) to 6063 T5. However, the heat from welding will locally soften the 5052 and the 6063. If this is not a highly stressed component or used under cyclic loading conditions, you should be ok. The following web site has various filler …Analyze the purlin as a beam with fixed ends and design your connection for that moment with a healthy amount of extra capacity. I am using the current code required snow loads. In my area, the required snow load is 35psf, so I am not overly worried about wind. JStructsteel (Structural) 1 Nov 22 12:45.Corrosion engineering. (24764 members) forum338 - Professional forum and technical support for engineers for Corrosion engineering. Includes problem solving collaboration tools. Forum. Search.Here are tried and tested tips for a successful first family vacation to Europe. Update: Some offers mentioned below are no longer available. View the current offers here. My famil...A guide to the most eco-friendly and sustainable luxury hotels in England. The impact that travel has on the planet is causing concern for an increasing number of travelers. Althou... Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Antenna & propagation engineering. Circuit design. Communication & signal processing engineering. Electric motors & generators engineering. Electric power & transmission & distribution. Electrical Engineering general discussion. Microwave & electromagnetic engineering. Power supply & electronic component design.The reason is carbon content below 0.03% would be considered 304L per the SA 240 material specification, and limited to 1000 deg F. When you have dual grade certification 304L/304, the 0.04% or higher carbon comes into play for creep strength and one must review the MTR for specific use. SnTMan (Mechanical) 14 …Beijing approves the first vaccine of its kind as it looks to jumpstart its flailing economy China has approved a Covid-19 vaccine utilizing MRNA technology for the first time ever...Mar 22, 2023 · From reading XR250s posts I think this is how he approaches it as well. 3. YoungGunner (Structural) 23 Mar 23 15:22. Having worked in residential for 7 years now, I have a few thoughts on the matter: First off, the IRC already shows questionable engineering compared to our "big boy" design standards/codes. .

Popular Topics